Shenzhen Zhongyuan Chuangda Technology Co., Ltd

      Bring brightness,warmness and hope.Fight for better future!

Sales & Support
Request A Quote - Email
Select Language
Home
Products
About Us
Factory Tour
Quality Control
Contact Us
Request A Quote
English
French
German
Italian
Russian
Spanish
Portuguese
Dutch
Greek
Japanese
Korean
HomeProductsHigh Frequency Online UPS

DSP 1000va 800w True Online UPS 220V UPS Power Supply For Communication

Bought 3pcs I33E80K 2 years ago, and just received return order from my client, quality and service is so far so good, more business will come soon.

—— Derek--South Africa

Encounted quality and delivery time delay problem with a supplier in China in 2014,It is lucky to find ZYUPS,a professional and reliable partner

—— Anthony--USA

Several successful transactions for 6kva and 10kva, we use for IT server solution, hope your products can bring us more business.

—— Christopher--Zambia

I'm Online Chat Now

DSP 1000va 800w True Online UPS 220V UPS Power Supply For Communication

DSP 1000va 800w True Online UPS 220V UPS Power Supply For Communication supplier DSP 1000va 800w True Online UPS 220V UPS Power Supply For Communication supplier DSP 1000va 800w True Online UPS 220V UPS Power Supply For Communication supplier

Large Image :  DSP 1000va 800w True Online UPS 220V UPS Power Supply For Communication

Product Details:

Place of Origin:China
Brand Name:IWELL
Certification:CE/FCC/ISO9001
Model Number:CE1K, CE1KS

Payment & Shipping Terms:

Minimum Order Quantity:1 piece
Price:Negotiation
Packaging Details:Inner box + shipping carton
Delivery Time:7-10 working days
Payment Terms:T/T, Western Union, L/C, D/P
Supply Ability:30,000pcs per month
Detailed Product Description
Phase: Single Phase Input/Output Voltage: 220VAC/ 120Vac/ 110Vac/ 100Vac/230Vac
Capacity: 1Kva, 1000va Frequency: 50/60Hz
Battery: Lead Acid Battery Application: Communication

CE1Ks Pure Sine Wave 1000va 800w  Single Phase High Frequency Online UPS

 

 

DSP Technology

Active input power factor correction (PFC)

Wide range of input voltage and frequency

Zero power switch delayWhen the utility power fails, UPS will automatically switch from AC mode to battery mode with no delay, which will ensures stable power supply of operating system. 

Active Load Management

Sufficient Expansion Slots

The load power factor is 0.8

 

Model# CE1K CE1KS Comments
Input voltage
Rated voltage  220VAC  
Phase Single phase with ground  
Turn on voltage range (90±5~285±5)VAC  
Bypass voltage range 80VAC~286VAC(default:80VAC~264VAC) Could be adjusted by software.
Bypass low loss  80VAC~220VAC(default:80VAC)
Bypass low comeback Low loss+10VAC
Bypass high loss 220VAC~286VAC(default:264VAC)
Bypass high comeback High loss -10VAC
Line low loss/comeback (90±5) VAC /(110±5) VAC load≤30% PF=0.7
(110±5)VAC/(125±5)VAC 30%<load≤60%
(120±5) VAC /(135±5) VAC 60%<load≤70%
(140±5) VAC /(155±5) VAC 70%<load≤80%
(160±5) VAC /(170±5) VAC load>80%
(90±5) VAC /(110±5) VAC load≤30% PF=0.8
(110±5) VAC /(125±5) VAC 30%<load≤55%
(130±5) VAC /(145±5) VAC 56%<load≤65%
(150±5) VAC /(165±5) VAC 66%<load≤70%
(160±5) VAC /(175±5) VAC load>70%
Line high loss/comeback (300±5)VAC/(285±5)VAC 0%≤load<100%
Input frequency 
Rated frequency 50Hz  
Frequency low loss (40~49)±0.2Hz(default:46Hz) Could be adjusted by software.
Frequency low comeback Frequency low loss + 0.5Hz  
Frequency high loss (51~60)±0.2Hz(default:54Hz)  
Frequency high comeback Frequency high loss - 0.5Hz  
Input power factor
Input power factor 0.99 220VAC,full R load
Generator Support generator input Generator rating≥2*UPS rating
Input current
Rated current 5A 220VAC,full RCD load
Input THDI ≤10% 220VAC,full RCD load, The mains THDI≤4%
Output protection
Rating protection 10A  AC fuse  
Output power
VA/watt 1000VA/700W~800W Could be adjusted by software.
Rated voltage 220VAC Pure Sine wave
Voltage range 200VAC/208VAC/220VAC/230VAC/240VAC Could be adjusted by software. 10% derating for 208VAC/200VAC.
Voltage regulation ±2%  
Voltage distortion ≤7% Full RCD load 220VAC;battery fully charged
≤4% Full R load
DC offset ≤±200mV  
Transient response ≤9% R load 0%~100%~0%
≤6% R load 20%~100%~20%
Transient recovery ≤60ms voltage recovery to 90% Full RCD load
Bypass output before turn-on Default:No Could be set by software.
Crest ration 3:01  
Output frequency range
Normal mode 1,Same as input frequency(46Hz~54Hz)  
2,50Hz(Input frequency>54Hz or  Input frequency<46Hz)
Battery mode 50±0.2Hz Line frequency out of range
Slew rate <1Hz/s  
Efficiency
Normal  mode >85% Battery fully charged
Battery mode >83%  
Overload
Normal mode/battery mode Overload warning only 100%±5%<load PF=0.7
60S,then transfer to bypass and alarm. 105%±5%<load≤125%±5%
30S,then transfer to bypass and alarm. 125%±5%<load≤150%±5%
300mS, then transfer to bypass and alarm.  load>150%±5%
Overload warning only 100%±5%<load PF=0.8
50S,then transfer to bypass and alarm. 105%±5%<load≤125%±5%
25S, then transfer to bypass and alarm. 125%±5%<load≤150%±5%
300mS,then transfer to bypass and alarm. load>150%±5%
Automatically retransfer Yes  
Short protection
Normal/battery mode Cut off output within 5 cycles  
Transfer time
Normal to battery mode 0ms  
Battery to normal mode 0ms  
Normal to bypass mode <4ms With load
Bypass to normal mode <4ms With load
Battery and charger
Battery
Rated voltage 36VDC According to the battery capacity and number  
Type/Rating 7AH/12V  
Battery quantity 3 PCS  
Backup time 6Min PF=0.7
5Min PF=0.8
Protection
Low alarm voltage / comeback voltage (32V±1V)/ (32.6V±1V) (34.5V±1V)/ (35.1V±1V) 70%<load
(33V±1V)/ (33.6V±1V) 30%<load≤70%
(34.5V±1V)/ (35.1V±1V) load≤30%
Shutdown voltage 30V±1V 32V±1V 70%<load
31.5V±1V 30%<load≤70%
33.5V±1V load≤30%
DC protection 40A/Fuse parallel  
Overcharge protection 45V±1V  
Over discharge protection 14 hour Could be set by software
Leakage current <150uA <500uA  
Battery test
Battery weak Yes  
Battery fault Yes  
Charger
Output voltage (41.25±1)VDC  
Charge time      
Input voltage range 80VAC~300VAC    
Charge current 1A 6.5A  
Interface
Alarm silence Yes  
DC power turn-on Yes  
Auto restart Yes  
Audio alarm
Battery mode Beep/4s  
Battery low/charger fault Beep/1s  
UPS fault Continue beep  
Overload Beep/1s  
Bypass mode Beep/2Min  
L/N inverse Beep/2Min  
Communication
RS232 interface Yes  
Intelligent slot Yes  
Monitor software Appending with UPS  
Cooling
Force air cooling    
Display
LCD/LED displays UPS status    
Environment
Work temperature 0℃~40℃  
Altitude <1000m  
Audible noise ≤45dB  
Storage temperature -15℃~45℃  
Work humidity 20%~95%  
Standard
EMS
ESD IEC61000-4-2 Level4
RS IEC61000-4-3 Level3
EFT IEC61000-4-4 Level4
Surge IEC61000-4-5 Level4
EMI
Conducted EN55022 Class A
Radiated EN55022 Class A
Safety
Safety GB4943-2001/IEC62040-1  
Transportation
Drop test GB-T4857-18  
Vibration test B-WR1-129(GB-T14715-93)  
Machinery features
Connection
Inlet Non-detachable power supply cord with GB plug  
Outlet GB socket  
External battery slot No Yes  
Optional functions
60Hz support  
Converter mode support  
ECO Optional  
EPO Optional  

   

DSP 1000va 800w True Online UPS 220V UPS Power Supply For Communication

DSP 1000va 800w True Online UPS 220V UPS Power Supply For Communication

Contact Details
Shenzhen Zhongyuan Chuangda Technology Co., Ltd

Contact Person: Mrs. ZYUPS

Tel:86-0755-83265008

Fax:86-0755-83208560

Send your inquiry directly to us (0 / 3000)

Other Products

High Tech Pure Sine Wave High Frequency Online UPS RS232 USB Port 1kva 36v

Long Backup Time Uniterrupted Power Suppy 10kva Online UPS With External AGM Battery

Online Powersafe UPS Monintoring 220v UPS Power Supply With AS400 Dry Contact Card

6kva 50hz High Frequency Online UPS Built In 12v Lead Acid Battery

RS232 220 V Double Conversion Online UPS 2kva Default Monitoring Power

Home Appliance Power High Frequency Online UPS SNMP Card Optional 3KVA

PF0.8 15KVA High Frequency Online UPS Single Phase UPS Systems